Detail HIOKI 3256-50, 3257-50, DIGITAL MULTIMETER, 085282731888/ 081908101888
HIOKI 3256-50, 3257-50, DIGITAL MULTIMETER Call Syihabudin 085282731888/ 081908101888
CAT III 600V
CAT II 1000V
3256-50 CAT IV 600V
3257-50 CAT III 1000V
For basic applications For industrial applications
3256-50 ( Average rectified type, with the carrying case as standard) 3257-50 ( True RMS rectified type, with the carrying case as standard)
Terminal shutter interlock mechanism for safety
3256-50: Average rectified type, AC voltage detection simply by placing the instrument close the insulated cable
3256-50: Overload protect up to 600V for all measurement functions ( V, © functions up to 1000V)
3257-50: True RMS type, Duty ratio measurement for pulse signal analysis
3257-50: Overload protect up to 1000V for all measurement functions
Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
Basic specifications ( Accuracy guaranteed for 1 year)
3256-50 3257-50
DC Voltage 420.0 mV to 1000 V, 5 ranges, Basic accuracy: ± 0.5 % rdg. ± 2 dgt.
AC Voltage / 50 to 500 Hz 420.0 mV to 1000 V, 5 ranges, Basic accuracy: ± 1.2 % rdg. ± 3 dgt., ( Average rectified) 420.0 mV to 1000 V, 5 ranges, Basic accuracy: ± 1.2 % rdg. ± 3 dgt., ( True RMS, crest factor 3)
Resistance 420.0 © to 42.00 M© , 6 ranges, Basic accuracy: ± 0.7 % rdg. ± 2 dgt.
DC Current 42.00 ¼ A to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ± 1.5 % rdg. ± 4 dgt.
AC Current / 50 to 500 Hz 42.00 ¼ A to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ± 2.5 % rdg. ± 5 dgt., ( Average rectified) 42.00 ¼ A to 420.0 mA, 10 A, 6 ranges, Basic accuracy: ± 2.5 % rdg. ± 5 dgt., ( True RMS, crest factor 3)
Hz ( Frequency) 199.99 Hz to 500.0 kHz, 5 ranges, Basic accuracy: ± 0.02 % rdg. ± 1 dgt., Input level: 0.8 V to 1000 V, 4 levels, Frequencies of less than 0.50 Hz cannot be measured
Duty ratio measure Not available 5 to 95 % , Frequency range: 10 Hz to 10 kHz, Basic accuracy: ± 1.0 % rdg. ± 15 dgt.
Voltage Detection Bring the top close to the power line, when the voltage is outside of the detection range, buzzer and the display blinks Not available
Continuity buzzer Threshold 50 © ± 40 © , Open terminal voltage: 3.4 V or less
Diode check Open terminal voltage: 3.4 V or less, Testing current: 700 ¼ A
Other function Relative value, Memory, Auto power save, Auto hold, Recoding ( Max./ Min. / Ave.)
Display Digital/ LCD, max. 4200 digits ( 19999 digits at frequency measure)
Sample rate 2.5 times/ s ( except Frequency) , 5 times/ s ( Frequency, over 5 Hz) , 25 times/ s ( Update of bar graph)
Power supply Manganese battery ( R03) × 2, Continuous use: 100 hours
Dimensions and mass 76W ( 2.99in) × 167H ( 6.57in) × 33D ( 1.30in) mm, 260 g ( 9.2 oz)
Supplied accessories TEST LEAD× 1, Instruction Manual× 1, Manganese batteries( R03) × 2 ( for trial purposes only) , CARRYING CASE 9378× 1
Hubungi toko DINS ( Digital Instruments)
Jl. Ciledug Raya Komplek. Taman Surya Buana Blok L19 - Kreo - Cipadu, Ciledug - Tangerang 15155
CP : Irfan Syihabudin
XL : 081908101888
AS : 085282731888
Tampilkan Lebih Banyak