Detail Fluke 54 II, Dual Input Digital Thermometer With Data Logging 085282731888
Fluke 54 II
Dual Input Digital Thermometer with Data Logging 085282731888
Relative time clock on MIN, MAX, and AVG provides a time reference for major events
Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
Measures J, K, T, R, S, N and E-types of thermocouples
Readout in º C, º F, or Kelvin ( K)
Splash and dust resistant case protected by impact absorbing holster
Large backlit dual display shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG.
Recall function allows logged data to be easily reviewed on the meter display
USB communication port allows data to be exported to optional FlukeView Forms Temperature PC software for further analysis and graphing
Data Logging up to 500 points of data with user adjustable recording interval
Click here for a larger image - Fluke 53IIB Dual Input Digital Thermometer with data loggingClick here for a larger image - Fluke 53IIB Dual Input Digital Thermometer with data logging
Fluke 54 II B Shown
Product Information
Manual 565 KB PDF
54 II B Demo Movie
Click here for Information Regarding PDF' sPDF Help
The Fluke 54 II B contact thermometer and data logger offers fast response and laboratory accuracy ( 0.05% + 0.3° C) in a rugged, handheld test tool
Specification Fluke 54 II B
Temperature accuracy Above -100 ° C: J, K, T, E, and N-type: ± [ 0.05% + 0.3° C] R and S-type: ± [ 0.05% + 0.4° C]
Below -100 ° C: J, K, E, and N-types: ± [ 0.20% + 0.3° C] T-type: ± [ 0.50% + 0.3° C]
Temperature J-type: -210 ° C to 1200 ° C
K-type: -200 ° C to 1372 ° C
T-type: -250 ° C to 400 ° C
E-type: -150 ° C to 1000 ° C
N-type: -200 ° C to 1300 ° C
R and S-type: 0 ° C to 1767 ° C
Temperature scale ITS-90
Applicable standards NIST-175
Display Resolution 0.1 ° C, 0.1 K = 1000
Environmental Specifications
Operating Temperature -10 ° C to 50 ° C
Storage Temperature -40 ° C to 60 ° C
Humidity ( Without Condensation) 0% to 90% ; 0 ° C to 35 ° C
0% to 70% ; 0 ° C to 50 ° C
Safety Specifications
Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1, 2
Agency Approvals CE, CSA, TÜ V ( pending)
Mechanical and General Specifications
Size 173 mm L x 86 mm W x 38 mm
Weight 400 g
Batteries 3 AA batteries; typical 1000-hour life
DIGITAL INSTRUMENTS | BUANA SURVEY JAKARTA 0217321129
JL. MUCHTAR RAYA NO. 1D, KREO - CILEDUG 15156
CP : IRFAN 081908101888
T : 0217321129 F : 0217302811 M : 081908101888
Tampilkan Lebih Banyak